Assembly Length |
<Positive numeric value>
- Sets overall horizontal length of the motor/pump subassembly.
|
Base Height |
<Positive numeric value>
- Sets the thickness of the base on which the motor/pump subassembly rests.
|
Base Length |
<Positive numeric value>
- Sets the length of the base on which the motor/pump subassembly rests.
|
Base To Casing Top Distance |
<Positive numeric value>
- Sets the vertical distance between the base and the top most portion of the pump housing.
|
Base To Center Elevation |
<Positive numeric value>
- Sets the vertical distance between the base and the center line axis of the motor/pump subassembly.
For the motor mounted pump, the base refers to the lowest point on the motor or pump housing.
|
Base To Discharge Length |
<Positive numeric value>
- Sets the vertical distance between the base and the center line axis of the pump discharge (End2).
|
Base To Inlet Elevation |
<Positive numeric value>
- Sets the vertical distance between the bottom of the motor and the center line axis of the pump housing.
This property applies to the vertically oriented pumps.
|
Base To Motor Top Distance |
<Positive numeric value>
- Sets the vertical distance between the base and the top most portion of the motor, equals base height and motor body height.
|
Base Width |
<Positive numeric value>
- Sets the width of the base on which the motor/pump subassembly rests.
|
Casing1 Radius |
<Positive numeric value>
- Sizes the radius of the first pump housing.
This property applies to the vertical dual arm pump. |
Casing2 Radius |
<Positive numeric value>
- Sizes the radius of the second pump housing.
This property applies to the vertical dual arm pump. |
Casing1 Total Offset |
<Positive numeric value>
- Sets the overall offset distance between the suction (End1) axis to the outer most portion of pump number one's housing.
This property applies to the vertical dual arm pump. |
Casing2 Total Offset |
<Positive numeric value>
- Sets the overall offset distance between the suction (End1) axis to the outer most portion of pump number two's housing.
This property applies to the vertical dual arm pump. |
Casing | Diameter |
<Positive numeric value>
- Sets the diameter of the pump housing.
|
Casing Height |
<Positive numeric value>
- Sets the height of the motor section.
|
Casing | Offset |
<Positive numeric value>
- Sets the horizontal offset distance between the pump intake (End1) and the front of the base.
|
Center To Box Offset |
<Positive numeric value>
- Sets the offset distance between the pump intake (End1) and the outer portion of the motor electrical connections box.
|
Center To Discharge Elevation |
<Positive numeric value>
- Sets the vertical offset distance between the pump intake (End1) and the outlet (End2).
|
Center To Discharge Length |
<Positive numeric value>
- Sets the vertical offset distance between the motor/pump axis and the motor flange surface.
|
Center To Discharge Offset |
<Positive numeric value>
- Sets the offset distance between the motor/pump axis and the discharge (End2) axis/ flange surface.
|
Center To Mount Offset |
<Positive numeric value>
- Sets the offset distance between the motor/pump axis and the discharge (End2) axis.
|
Center To Suction Length |
<Positive numeric value>
- Sets the vertical offset distance between the motor/pump axis and the motor mount bottom surface.
|
Center To Suction Offset |
<Positive numeric value>
- Sets the offset distance between the motor/pump axis and the suction (End1) flange.
|
Collector Height |
<Positive numeric value>
- Sets the height of the collector between inlet and discharge manifolds.
|
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Connection | Length |
Positive <numeric value>
- Sets length of straight portion at connection at END1.
|
Connection Offset Discharge |
<Positive numeric value>
- Sets the offset between discharge connection at End2 and the center, towards base.
|
Connection Offset Suction |
<Positive numeric value>
- Sets the offset between suction connection at End1 and the center, towards base.
|
Diaphragm Connector Diameter |
<Positive numeric value>
- Sets the diameter of the diaphragms within pump width.
|
Diaphragm Connector Length |
<Positive numeric value>
- Determines the length of the shaft connecting air chambers containing the diaphragms.
|
Discharge | Connection Length |
<Positive numeric value>
- Sets the straight length at the End2 outlet.
|
Discharge Outer Diameter |
Positive <numeric value>
- Run outside diameter at End2.
- Main outside diameter at inlet.
|
Discharge Side Offset |
<Positive numeric value>
- Sets the curvature radius at the flange surface of base around the discharge outlet.
|
Discharge To Motor End Distance |
<Positive numeric value>
- Sets the horizontal distance between the pump discharge axis (End2) and the opposite end of the motor.
|
Discharge To Suction Length |
<Positive numeric value>
- Sets the horizontal offset distance between the pump discharge axis (End2) and the pump suction flange surface (End1).
|
Discharge Type |
- 1-Horizontal - End2 Outlet Horizontal.
- 2-Vertical - End2 Outlet Vertical.
- 3-Side - Both suction inlet (end1) and Outlet are at side.
- Sets the discharge type of the pump to one of the above options.
|
Flow Rate |
<Positive numeric value>
- Sets a value for the amount of flow through pump. Used to calculate overall flow rate during analysis operations.
|
Half Casing Length |
<Positive numeric value>
- Sets the size of the pump housing from the outermost surface to the suction and discharge axis.
|
Inline Length |
<Positive numeric value>
- Sets the overall distance between suction (End1) and discharge (End2) flange surfaces when they are inline.
|
Motor | Body Height Motor | Body Length
Motor | Body Width |
<Positive numeric value>
- Sets dimension of sides of motor housing, usually in rectangular body.
|
Motor | Diameter |
<Positive numeric value>
- Sets the diameter of the motor section.
|
Motor 1 | Diameter |
<Positive numeric value>
- Sets the first motor diameter.
|
Motor 2 | Diameter |
<Positive numeric value>
- Sets the second motor diameter.
|
Motor Height |
<Positive numeric value>
- Sets the height of the pump housing.
|
Motor | Over Shoot |
<Positive numeric value>
- Sets the distance between the motor's end surface when it overshoots the base.
|
Motor | Rotation |
-
1–leftHanded
-
2–rightHanded
- Sets the motor rotation. Pump outlet is rotated to clockwise for right handed orientation, and counter clockwise for left handed orientation.
|
Motor | Mount Length |
<Positive numeric value>
- Sets the length dimension for the motor mount.
Mount is maintained centered under motor. |
Motor | Mount Width |
<Positive numeric value>
- Sets the width dimension for the motor mount.
Mount is maintained centered under motor. |
Offset Between Collectors |
<Positive numeric value>
- Sets the horizontal distance between elbows connecting the manifold.
|
Offset Between Pumps |
<Positive numeric value>
- Sets the offset distance between outer surfaces of pumps.
|
Pump Height |
<Positive numeric value>
- Sets overall length of the assembly of a vertical . pump, for example, Jockey Pump.
|
Pump Length |
<Positive numeric value>
- Sets the length for suitable displacement of diaphragm in the chamber.
|
Pump To Base Offset |
<Positive numeric value>
- Sets the offset distance between the pump axis and the base.
|
Pump Width |
<Positive numeric value>
- Sets the width for the pump chambers.
|
Suction | Connection Length |
<Positive numeric value>
- Sets the straight length at the End1 outlet.
|
Suction Outer Diameter |
Positive <numeric value>
- Inlet outside diameter at inlet.
|
Suction Side |
-
1–leftHanded
-
2–rightHanded
- Sets the suction (End1) orientation to right or left side. Discharge is oriented to the opposite side of the pump housing.
|
Suction To Casing1 Center |
<Positive numeric value>
- Sets the horizontal offset distance between the suction (End1) flange surface to the central axis of pump number one.
This property applies to the vertical dual arm pump. |
Suction To Casing2 Center |
<Positive numeric value>
- Sets the horizontal offset distance between the suction (End1) flange surface to the central axis of pump number two.
This property applies to the vertical dual arm pump. |
Total Height |
<Positive numeric value>
- Sets the height from the base to the discharge port/manifold End 2 surface. Specifies the total height of the pump assembly.
It is the sum of H2, H3 and the Base Height. Total Height covers Collector Height and the Base Height.
|
Transition1 Length, Transition2 Length |
<Positive numeric value>
- Sets the length of the transition coupling the pump manifolds with End1 and End2 respectively.
|