Base | Length |
Positive <numeric value>
- Sets length of base board.
|
Base To Heater Bottom Distance |
Positive <numeric value>
- Sets width of blades stacked on back surface of unit providing directional outlet.
|
Blades Width |
Positive <numeric value>
- Sets width to pair of boards beneath heater panels.
|
Board Width |
Positive <numeric value>
- Sets width to pair of boards beneath heater panels.
|
Box | Height |
Positive <numeric value>
- Sets the height of a equipment Box (e.g. Radiator module).
|
Box | Length |
Positive <numeric value>
- Sets the length of a Box (Radiator module).
|
Box | Width |
Positive <numeric value>
- Sets the width of a equipment Box (e.g. Radiator module).
|
Connection 1 | Length (L1) |
Positive <numeric value>
- Sets the straight length at End1.
|
Connection 2 | Length (L2) |
Positive <numeric value>
- Sets the straight length at End2.
|
Connection 3 | Length (L1) |
Positive <numeric value>
- Sets the straight length at End3.
|
Carrying Bar Height |
Positive <numeric value>
- Sets height of carrying bars connecting the fixed body and rear support column.
|
Carrying Bar Width |
Positive <numeric value>
- Sets width of carrying bars in plate heat exchanger.
|
Cell Library |
<cell library file name>
|
Cell Symbol Name |
<cell name>
- Sets the model cell to the device.
Prerequisite of proper Cell Library for AHUs. |
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Connection Side |
Sets inlet and outlet connections to either Left or Right side of unit. |
Control | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Control Assembly on one of the sides of the cooler.
|
Control | Height Control | Length
Control | Width |
Positive <numeric value>
- Sets dimensions of sides of control box assembly.
|
Control | Side Offset |
Positive <numeric value>
- Sets offset distance between control box assembly and side of box.
|
Control | Top Offset |
Positive <numeric value>
- Sets offset distance between control box assembly and top of box.
|
Depth |
Positive <numeric value>
- Sets depth dimension of equipment body (heater/cooler unit).
|
Drain | Bottom Offset |
Positive <numeric value>
- Sets offset distance between drain outlet and top of equipment box.
|
Drain | Diameter |
Positive <numeric value>
- Sets outside diameter of drain outlet.
|
Drain | Length |
Positive <numeric value>
- Sets length of drain outlet.
|
Drain | Side Offset |
Positive <numeric value>
- Sets offset distance between drain outlet and side of box.
|
Electric Supply | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Electric Supply connection on one of the sides of the cooler.
|
Electric Supply | Diameter |
Positive <numeric value>
- Sets outside diameter of Electric Supply connection.
|
Electric Supply | Side Offset |
Positive <numeric value>
- Sets offset distance between Electric Supply connection and side of box.
|
Electric Supply | Top Offset |
Positive <numeric value>
- Sets offset distance between Electric Supply connection and top of box.
|
Fan Connection Side |
- Sets side for fans connection.
5-Top - Default side for Axial Cooling Tower. |
Fan Diameter |
Positive <numeric value>
- Sets diameter of axial fans.
|
Fan Height |
Positive <numeric value>
- Sets height of fans used in equipment.
|
Fan Length |
Positive <numeric value>
- Sets length of fans used in equipment.
|
Fan Location |
Sets fans location on the side of equipment (e.g. cooling tower). |
Fan Type |
- Sets type of fan used in equipment (e.g. in cooling tower).
|
Fan Width |
Positive <numeric value>
- Sets width of fans used in equipment.
|
Fixed Body Height |
Positive <numeric value>
|
Fixed Body Thickness |
Positive <numeric value>
|
Fixed Body Width |
Positive <numeric value>
|
With Rear Support Bar |
true
- Sets Rear Support Bar to Plate Heat Exchanger.
false
- Sets no Rear Support Bar.
The Rear Support Bar is set parallel to and of equal height to Fixed and Movable body. |
Height |
Positive <numeric value>
- Sets height dimension of equipment body (heater/cooler unit).
|
Inlet 1 | Outer Diameter Outlet 1 | Outer Diameter
Inlet 2 | Outer Diameter Outlet 2 | Outer Diameter
|
Positive <numeric value>
- Sets diameters of inlet and outlet connection ports seen on Fixed Body cover, values as defined for D1 to D4 respectively.
|
Inlet | Top Offset |
Positive <numeric value>
- Sets offset to Inlet connection from top of equipment body.
|
Inlet | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Inlet connection on one of the sides of the cooler.
|
Inlet | Diameter |
Positive <numeric value>
- Sets outside diameter of Inlet connection in equipment (e.g. in cooling tower).
|
Inlet | Length |
Positive <numeric value>
- Sets length of Inlet connection in equipment (e.g. at End2 in unit heater).
|
Inlet | Offset Between Inlets |
Positive <numeric value>
- Sets distance between two inlets, when Number of Inlets are more than 1.
|
Inlet | Side Offset |
Positive <numeric value>
- Sets offset distance between Inlet connection and side of equipment body.
|
No. of Grille Bars |
<integer>
- Sets number of grille bars on grille surface. In case of baseboard, across the bases.
|
Length |
Positive <numeric value>
- Sets length dimension of equipment body (heater/cooler unit).
|
Loop1 Connection Offset |
Positive <numeric value>
- Sets offset distance between Loop1 Port (End2 connect point) and top of Plate Pack of Plate Heat Exchanger.
|
Loop1 Side Offset |
Positive <numeric value>
- Sets offset distance between Loop1 Ports (End1 and End2) and side of Plate pack of Plate Heat Exchanger.
|
Loop1 Top Offset |
Positive <numeric value>
- Sets offset distance between Loop1 Ports (End1 and End2) and top edge of Plate pack of Plate Heat Exchanger.
|
Loop2 Connection Offset |
Positive <numeric value>
- Sets offset distance between Loop2 Port (End4 connect point) and top of Plate Pack of Plate Heat Exchanger.
|
Loop2 Side Offset |
Positive <numeric value>
- Sets offset distance between Loop2 Ports (End3 and End4) and side of Plate pack of Plate Heat Exchanger.
|
Loop2 Top Offset |
Positive <numeric value>
- Sets offset distance between Loop2 Ports (End3 and End4) and top edge of Plate pack of Plate Heat Exchanger.
|
Motor | Diameter |
Positive <numeric value>
- Sets diameter of motor mounted on the unit.
|
Motor | Body Length |
Positive <numeric value>
- Sets length of motor mounted on the unit.
|
Movable Body | Height |
Positive <numeric value>
- Sets height of movable body, equal to height of Fixed Body.
|
Movable Body | Width |
Positive <numeric value>
- Sets width of movable body, equal to width of Fixed Body.
|
Inlet | Number Of Inlets |
<numeric value> between 1 and 2
- Sets number of inlets to cooler.
|
Number of Plates |
<integer>
- Sets number of plates in the pack of Plate Heat Exchanger.
|
Plate Offset |
Positive <numeric value>
- Sets offset distance between Fixed Body and Movable Body covers of Plate Heat Exchanger.
|
Frame Offset |
Positive <numeric value>
- Sets offset distance between Movable Body and Rear Support Bar of Plate Heat Exchanger.
|
Opening Height |
Positive <numeric value>
- Sets height of the opening on side of Axial Cooling Tower unit.
|
Outlet | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Outlet connection on one of the sides of the cooler.
|
Outlet | Diameter |
Positive <numeric value>
- Sets outside diameter of Outlet connection in equipment (e.g. in cooling tower).
|
Outlet | Length |
Positive <numeric value>
- Sets straight length of outlet connection at End2.
|
Outlet | Side Offset |
Positive <numeric value>
- Sets offset distance between Outlet connection and side of equipment body.
|
Outlet | Top Offset |
Positive <numeric value>
- Sets offset to Outlet connection from top of equipment body.
|
Overflow Diameter |
Positive <numeric value>
- Sets outside diameter of Overflow connection at End1 in equipment (e.g. in cooling tower).
|
Overflow Side Offset |
Positive <numeric value>
- Sets offset distance between Overflow connection and side of equipment body.
|
Overflow Top Offset |
Positive <numeric value>
- Sets offset to Overflow connection (End1) from top of equipment body.
|
Plate Height |
Positive <numeric value>
- Sets height of the Plate pack embedded in Fixed and Movable Body of Plate Heat Exchanger.
|
Plate Width |
Positive <numeric value>
- Sets width, within Body Width of the Plate pack embedded in Fixed and Movable Body of Plate Heat Exchanger.
|
Rear Support Bar Height |
Positive <numeric value>
- Sets height to Rear Support Bar, value equals to the height set in Fixed Body Height.
|
Rear Support Bar Thickness |
Positive <numeric value>
- Sets thickness to Rear Support Bar, value equals to the width set in Fixed Body Width.
|
Rear Support Bar Width |
Positive <numeric value>
- Sets width of Rear Support Bar.
|
Return | Diameter |
Positive <numeric value>
- Sets outside diameter of Return Outlet.
|
Return | Length |
Positive <numeric value>
- Sets the straight length of Return Outlet.
|
Return | Side Offset |
Positive <numeric value>
- Sets offset distance between Return connect point and side of box.
|
Return | Top Offset |
Positive <numeric value>
- Sets offset distance between Return connect point and top of box.
|
Tag |
<alpha-numeric characters>
|
Tightening Bolt Diameter |
Positive <numeric value>
- Sets diameter of the tightening bolts screwed on the bar connecting the Fixed and Movable Bodies to Rear Support.
|
Tightening Bolt Length |
Positive <numeric value>
|
Total Height |
Positive <numeric value>
- Sets total height of entire unit, proportional to Row value.
|
Total Length (L) |
Positive <numeric value>
- Sets total height of entire unit, proportional to Column value.
|
Total Width |
Positive <numeric value>
- Sets total width of entire unit, proportional to Row value.
|
Water Makeup Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Water Makeup connection on one of the sides of the cooler.
|
Water Makeup Diameter |
Positive <numeric value>
- Sets outside diameter of Water Makeup connection in equipment (e.g. in cooling tower).
|
Water Makeup Side Offset |
Positive <numeric value>
- Sets offset distance between Water Makeup Connection and side of box.
|
Water Makeup Top Offset |
Positive <numeric value>
- Sets offset to Water Makeup connection from top of equipment body.
|
Width |
Positive <numeric value>
- Sets width dimension of equipment body (heater/cooler unit).
|