Syntax for Running Standards Checks in the Batch Process Utility
In the batch process command file, the syntax for the Standards Checker execution command is: standardschecker execute [keyword=value,keyword=value...], where the keywords set the standards checker operational parameters.
The possible keywords and values are:
Keyword | Values |
---|---|
report | true, false, 0 or 1 If true or 1, a report file is generated |
interactive | true, false, 0 or 1 If true or 1, the Standards Checker is run in interactive mode. If the Batch Process runs in non-graphics mode, this keyword is ignored. |
settingsfile | File specification for the settings DGNLib file. If the path is not specified, OpenUtilities Substation searches the directory specified by the MS_SETTINGSDIR configuration variable. If the MS_STANDARDSCHECKER_SETTINGSFILE configuration variable is set, this keyword is ignored. |
settingsname | The named standards check settings to be used within the settings file. |
reportfile | File specification for the Standards Checker report file. If the directory is not specified, the file is put in the directory specified by the MS_STANDARDSCHECKER_OUT configuration variable. |
reportopen | overwrite, append, or new If not set (and report is set to 1 or true), a new report file is generated. |
reviewignored | true, false, 0, or 1 If true or 1, then problems previously marked as ignored are displayed in interactive mode. If the Standards Checker is not run in interactive mode, this keyword has no effect. |
The keyword/value pairs can be separated by either commas or spaces. Any value that includes a space or a comma can be specified by using double quotes either around the entire keyword/value pair, or around just the value portion, such as: "reportfile=C:\ProgramData\Bentley\<product_name> CONNECT Edition\Configuration\WorkSpaces\Example\WorkSets\General\Out\check.xml" or reportfile="C:\ProgramData\Bentley\<product_name> CONNECT Edition\Configuration\WorkSpaces\Example\WorkSets\General\Out\check.xml" .