Near/Far Lap Splice Preferences
|
- Maximum
Stock – Sets the percentage to use laps at the maximum bar length.
Type a percentage in the
% Over field to allow this amount over
the maximum length.
- Uniform
Length – When checked, makes the bar lengths along all equal.
- Stagger
Laps– Staggers the bar laps by the indicated distance set in the
next field.
|
Lap Data
|
Settings available to both Near and Far laps, each
in Horizontal / Vertical direction.
- Lap
Method – Sets the method for the lap, selected one from the three
options:
Length,
Bar Diameter, and
Mechanical Device.
- Lap
Length / Multiplier
– When
Length is selected as the Lap Method , this
value set in the adjacent field will be used for bar laps.
When
Bar Diameter is selected as the Lap Method,
then type the diameter multiplier to use and the calculated lap length is shown
in the
Multiplier field.
It is disabled for
Mechanical Device method.
- Stock
Length – Type the bar stock length for the bar size used (default
is 60'-0").
- Mil
Length – Type the manufactured length for the bar size used
(default is 60'-0").
|