Touching Tolerance
|
Sets the allowable distance used to eliminate
interferences between components that only touch. The default tolerance is 1
mm, which is converted into the working units of the active model. If the units
of the active model are not set to mm, this value will be different. The
maximum value is 10 cm. The less than (<) symbol indicates that there is a
non-zero value, which is smaller than the display preference. Unit type for the
model is set in the Working Units category of the Design File Settings dialog.
CLASHDETECTION
TOLERANCE
<value>
|
Suppress clashes between elements that are touching
|
If on, ignores elements that are within the
tolerance, such as when a pipe flange is bolted to an equipment nozzle or a
wall is connected to the floor.
CLASHDETECTION
SUPPRESSTOUCHING
[OFF | ON]
|
Clash Discovery Limit
|
Sets the maximum number of clashes that are
reported; default is 10,000.
CLASHDETECTION
DISCOVERYLIMIT
<value>
|
Clustering Tolerance
|
This is used to merge clashes when multiple areas of
the pointclouds are clashing with a single element. For example, if the
Clustering Tolerance is set to 100mm and a Slab is clashing with different
parts of the pointcloud, the software will try to split the clash into multiple
parts that are 100mm or more apart.
|
Maximum Points to Highlight
|
Sets the maximum number of point clashes that are
reported; default is 200,000.
CLASHDETECTION_ENGINE_MAX_POINTS_HIGHLIGHT
<value>
|