D8.C.4 Design Parameters
The following table contains the input parameters for specifying values of design variables and selection of design options.
Parameter Name | Default Value | Description |
---|---|---|
CODE | - | Must be specified as IS801
準拠する設計コード。「TR.48.1 パラメータの設定」を参照してください。 |
BEAM |
1.0 |
When this parameter is set to
|
CB | 0 | Bending coefficient Cb used for bending checks. By default (value of 0), this is calculated by the program. |
CMY | calculated | Coefficient Cm as per Cl. 6.7 for bending about the member Y axis. See IS:801-1975, 6.7. Used for Combined axial load and bending design. Values range from 0.4 to 1.0. |
CMZ | calculated | Coefficient Cm as per Cl. 6.7 for bending about the member Z axis. See IS:801-1975, 6.7. Used for Combined axial load and bending design. Values range from 0.4 to 1.0. |
CWY | 0 |
Specifies whether the cold work of forming strengthening effect should be included in resistance computation. See IS:801-1975, 6.1.1
|
FLX | 0 |
Specifies whether the member has torsional-flexural buckling restraints that will in turn determine whether the member is susceptible to flexural-torsional bucking mode. See IS:801-1975, 6.6.1
|
FU |
450 MPa (4588.72 kg/cm2) |
Ultimate tensile strength of steel in current units. |
FYLD |
353.04 MPa (3600.0 kg/cm2) |
Yield strength of steel in current units. |
KX | 1.0 | Effective length factor for torsional buckling. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression. |
KY | 1.0 | Effective length factor for overall buckling about the local Y-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression. |
KZ | 1.0 | Effective length factor for overall buckling in the local Z-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression. |
LX | Member length | Unbraced length for twisting. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from torsional buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression. |
LY | Member length | Effective length for overall buckling in the local Y-axis. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression. |
LZ | Member length | Effective length for overall buckling in the local Z-axis. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression. |
NSF | 1.0 | Net section factor for tension members. The net area is calculated as NSF×gross area. |
RATIO | 1.0 | Permissible ratio of actual to allowable stresses |
TRACK | 0 |
This parameter is used to control the level of detail in which the design output is reported in the output file. The allowable values are:
|
TSA | 0 |
Specifies whether transverse web stiffeners have been provided to check for the requirements of IS:801-1975, 5.2.4.
|
UNL | Member length | Unsupported length (in current units) for calculating the allowable bending stress. |