D5.B.9.1 Clause 6.1 – General
The partial safety factors will use the following values:
- Resistance of cross-sections, γM0 = 1.0
- Resistance of members to instability, γM1 = 1.0
- Resistance of cross sections to tension, γM2 = 1.1
The design function in STAAD.Pro sets these values as the default values for the SS-NA (NA 7 is specified).
Note: You can change these values through the GM0, GM1, & GM2 design parameters. Refer to
D5.A.6 設計パラメータ