D7.A.7 Design Parameters
You are allowed complete control over the design process through the use of parameters described in the following table. These parameters communicate design decisions from the engineer to the program. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements of the situation, some or all of these parameter values may have to be changed to exactly model the physical structure.
Parameter Name | Default Value | Description |
---|---|---|
CODE | - |
Must be specified as DIN18800. 準拠する設計コード。「TR.48.1 パラメータの設定」を参照してください。 |
BEAM | 0.0 |
Number of sections to be checked per member:
|
CB | 0 | Beam coefficient n, defined in Table 9: If Cb = 0, program will use n = 2.5 for rolled sections and 2.0 for welded sections. |
CMM | 1.0 |
Moment factor, Zeta, defined in Table 10:
|
DMAX | 1.0 m | Maximum allowable depth during member selection |
DMIN | 0.0 m | Minimum required depth during member selection |
KY | 1.0 | K value in local y-axis. Usually, this is the minor axis. |
KZ | 1.0 | K value in local z-axis. Usually, this is the major axis. |
LY | Member Length | Length in local y-axis to calculate slenderness ratio. |
LZ | Member Length | Length in local z-axis to calculate slenderness ratio. |
PY | 240 N/sq.mm | Strength of steel. |
NSF | 1.0 | Net section factor for tension members. |
RATIO | 1.0 | Permissible ratio of actual to allowable stresses |
SAME | 0.0 |
Control of sections to try during a SELECT process:
|
SBLT | 0 |
Specify section as either rolled or built-up:
|
SGR | 0.0 |
Grade of steel:
|
TRACK | 0.0 |
Level of detail in output file:
|
UNF | 1.0 | 曲げねじり座屈の計算に使用される、実際のメンバー長の割合として与えられる支点間距離。 |
UNL | Member Length | 許容曲げ応力を計算するための支点間距離。曲げねじり座屈の計算に使用されます。値は長さの現単位のものです。 |