T.3 Add temperature load case
- Create a primary load case titled Temperature Load and then select it in the status bar.
- In the program status bar, select 3: Temperature Load as the current load case.
-
To generate and assign the third load type:
-
On the
Loading ribbon tab, select the
Load Items tool in the
Loading Specifications group.
The Add New Load Items dialog opens. - Select the Temperature option under the Temperature Loads item.
- Type 40 in the Temperature Change for Axial Elongationfield.
-
Type
30 in the
Temperature Differential from Top to
Bottom field.
Leave the Temperature Differential from Side to Side (Local Z) field as 0 (default).
- Click Add and then click Close.
-
On the
Loading ribbon tab, select the
Load Items tool in the
Loading Specifications group.
- Assign the temperature load case to all of the elements: